Dispensers and controllers regulate how adhesives, sealants, coatings and other fluids are delivered to an assembly. Options range from hand-operated cartridge applicators to timed pneumatic dispensers, controlled valves and positive-displacement systems for demanding material applications.

Krayden supports technologies including Techcon dispensers and controls, medmix MIXPAC™ and COX™ applicators, and Nordson EFD dispensing solutions. The appropriate approach depends on the package, material behavior, required deposit and degree of process control.

Review viscosity, filler content, mix ratio, dispense rate and positional requirements alongside the operator or automation interface. The complete material path matters as much as the controller settings. Contact our technical team →

Frequently asked questions

How does time-pressure dispensing work?

A controller applies air pressure for a defined period to push material through an outlet. Deposit size depends on pressure and time, as well as viscosity, tip geometry, material level and trapped air. Stable material and supply conditions improve repeatability.

When should I consider positive-displacement dispensing?

Consider it when volumetric control is important or when the application is difficult to stabilize with time-pressure dispensing. Progressive-cavity and other metering technologies still need evaluation for the material, filler content, delivery pressure and required shot size.

What determines compatibility with a manual cartridge gun?

Check cartridge geometry, capacity, volumetric ratio, outlet orientation and the required plunger configuration. Also consider material viscosity, mixer resistance and required dispensing force. An applicator must match the exact cartridge system and intended operating conditions.

What is the purpose of suck-back or vacuum control?

It can help reduce dripping or material tailing between dispenses on suitable systems. Excessive vacuum may draw air into the outlet or disturb material delivery. Adjust within the equipment instructions and confirm the result at the required deposit size.

Why do shot sizes change during a production run?

Possible causes include temperature or viscosity changes, material curing in the tip, trapped air, unstable pressure or a changing supply condition. Check the material path and setup before changing controller settings. A restricted tip can mask the underlying issue.

Can a dispenser be connected to a robot or production line?

Many systems offer external triggering or integration options, but the available signals and control functions vary by model. Confirm electrical interfaces, timing, motion coordination and any valve or pump requirements before specifying the production setup.


Learn more

Choose the delivery method around the material

The dispenser must deliver the required deposit without damaging or prematurely curing the material. Viscosity, filler loading, work life and sensitivity to pressure or shear can affect the choice.

For cartridge systems, start with the package and mix ratio. For precision dispensing, review the complete flow path, controller, valve or pump, and tip as a working combination.

Pneumatic dispensing controller connected to an industrial syringe barrel with a foot pedal and bonding coupon

Manual and pneumatic applicators

Cartridge applicators are practical for assembly, sealing and repair processes.

  • Match the cartridge family, capacity and ratio.
  • Review the force needed to move the material through its mixer.
  • Consider operator workload, access and bead requirements.
  • Check the rated air supply for pneumatic applicators.

Controlled bench and automated dispensing

Select a control method suited to deposit size and process variation.

  • Timed air dispensing for appropriate syringe applications.
  • Dispense valves selected for chemistry and viscosity.
  • Positive-displacement metering for suitable volumetric applications.
  • External triggering and programmed motion where required.

Dispensing approaches compared

Approach Typical fit Variables to review
MIXPAC™ / COX™ manual applicators Operator-applied beads and assembly work. Cartridge fit, ratio, force and operator control.
Pneumatic cartridge applicator Cartridge dispensing where air assistance is useful. Air supply, regulated pressure and start-stop behavior.
Techcon TS250 / TS350 time-pressure dispensers Controlled dots, beads and fills from suitable packages. Pressure, time, viscosity, tip and air management.
Valve-controlled dispensing Applications requiring flow control near the outlet. Wetted materials, valve action and fluid supply.
Techcon TS8100 progressive-cavity technology Applications requiring controlled volumetric delivery. Material suitability, wear, calibration and delivery conditions.

Set up and verify the actual deposit

Use representative material and parts when establishing the process. Check deposit mass or volume, placement, cutoff and consistency through a production run, including pauses and restarts. Record the validated setup for repeat use.